Amps to Watts Calculator (DC, AC and 3-Phase)

16 amps on a 230 V single-phase supply is 2,944 watts at a power factor of 0.8, and 3,680 W for a heater with a power factor of one. Watts = amps × volts × power factor; DC uses a power factor of one, and three-phase multiplies by the square root of three.

Amps from a clamp meter, the appliance label, or the breaker or socket rating you want to check.

For three-phase enter the current in one line wire; the calculator adds the other two.

Leave blank for standard mains: 230 V single-phase or 400 V three-phase line to line. For DC enter the battery voltage; for the US enter 120.

1 for heaters and other resistive loads; about 0.8 for motors, ACs and mixed home loads. Ignored for DC.

Real power 2,944 W
Apparent power 3,680 VA
Real power in kW 2.94 kW

How this result was calculated

1 × 16 A × 230 V × 0.8 power factor = 2,944 W (2.94 kW). The first factor is one for DC and single-phase and √3 for three-phase, where the volts are line-to-line and the amps are per line. Without the power factor the result is 3,680 VA, the apparent power the wires carry. On DC the power factor is one.

Key facts

  • Watts = amps × volts × power factor. 16 A at 230 V and a power factor of 0.8 is 2,944 W, out of 3,680 VA of apparent power.
  • One amp on a 230 V supply carries 230 W of heating load; on a 12 V battery one amp carries only 12 W.
  • A 15 A circuit at 120 V (common in the US) carries at most 1,800 W of heating load before the breaker's rating is reached.
  • On three-phase, 10 A per line at 400 V and a power factor of 0.8 is 5,543 W, because three lines share the load.

Formula

DC: P = V × I; single-phase AC: P = V × I × PF; three-phase AC: P = √3 × V × I × PF

  • P = real power in watts (W); kW = W ÷ 1,000
  • I = current in amps (A), per line for three-phase
  • V = voltage: battery voltage for DC, phase-to-neutral for single-phase, line-to-line for three-phase
  • PF = power factor between 0 and 1; V × I without PF is the apparent power in VA
  • √3 ≈ 1.732, three-phase only

One amp is how many watts?

It depends on the voltage. On 230 V mains with a heating load, one amp is 230 W. On a 12 V battery, one amp is just 12 W. For motors and ACs, multiply by the power factor as well, so one amp delivers less real power than the volts suggest.

How many watts can a circuit or breaker handle?

Multiply the breaker's amps by the voltage. A 16 A circuit on 230 V carries 3,680 VA, which is 3,680 W of heaters but only 2,944 W of motors and ACs at a power factor of 0.8. The chart below lists the common breaker sizes.

That figure is the ceiling, not a target. A load that runs for hours should stay well under it: the wiring calculators on this site size cables at 1.25 times the running current, and starting surges of motors and compressors come on top.

Amps to watts on three-phase

Choose three-phase and enter the current in one line. The calculator uses the line-to-line voltage (400 V in Pakistan) and the square root of three: 10 A per line at a power factor of 0.8 is 5,543 W. If you know the kW and need the current, the 3 phase amps calculator works the other way.

Watts versus VA: why there are two answers

Volts × amps gives volt-amperes (VA), the apparent power the cable and breaker carry. Real watts are VA × power factor, the power that turns into heat, light or motion and that the meter counts. For a heater both are equal; for a motor the watts are lower. UPS and generator ratings in VA or kVA follow the same rule.

Worked examples

1 amp at 230 V: how many watts?

1 A × 230 V × 1 = 230 W for a heating load. With a power factor below one, the same amp carries fewer real watts.

10 amps to watts at 230 V

10 A × 230 V × 1 = 2,300 W (2.3 kW). That is roughly one large room heater or a kettle and an iron together.

How many watts can a 15 A circuit at 120 V handle?

15 A × 120 V × 1 = 1,800 W at most for heating loads. Long-running loads should stay well below this so the cable and breaker do not run at their limit.

20 amps from a 12 V battery

20 A × 12 V = 240 W. DC has no power factor, so the watts are simply volts times amps.

10 amps per line on three-phase 400 V

√3 × 400 V × 10 A × 0.8 = 5,543 W (5.54 kW). The apparent power is 6,928 VA.

Amps to watts chart for common breaker and socket ratings on single-phase 230 V (heating load, power factor one)

Breaker or socket ratingMost watts it can carryIn kW
6 A1,380 W1.38 kW
10 A2,300 W2.3 kW
13 A2,990 W2.99 kW
16 A3,680 W3.68 kW
20 A4,600 W4.6 kW
32 A7,360 W7.36 kW
40 A9,200 W9.2 kW
63 A14,490 W14.49 kW

Common mistakes

  • Multiplying amps by volts for a motor or AC and calling it watts. That is VA; the real watts are lower by the power factor (about 0.8).
  • Loading a circuit right up to the watts in the chart. Those are ceilings; a heater or AC running for hours should leave a margin, and motors surge above their running current at start-up.
  • Using 230 V with the three-phase formula. Three-phase uses the line-to-line voltage (400 V) and the square root of three, with the current of one line.
  • Copying a US chart for a 230 V supply. The same amps carry about twice the watts at 230 V as at 120 V, so always use the voltage of your own supply.

Safety: The watts a breaker allows are a ceiling for the circuit, not permission to add loads. Before putting a heater, AC or motor on an existing circuit, check the cable size with the wire size calculator and have a licensed electrician confirm the circuit.

Frequently asked questions

1 amp is how many watts?

230 W on a 230 V supply with a heating load. With a power factor of 0.8 (motors, mixed loads) it is less, and on a 12 V battery one amp is only 12 W.

What is 10 amps in watts?

2,300 W at 230 V with a power factor of one, or 2.3 kW.

How many watts is 16 A at 230 V?

3,680 W for heating loads and 2,944 W at a power factor of 0.8. A 16 A socket circuit can carry one large heater or AC, but not several at once.

How many watts can a 15 amp circuit handle?

At 120 V the ceiling is 1,800 W for heating loads. Loads that run for hours should stay well below it, and motors and ACs need room for their starting surge.

What is the amps to watts formula?

Watts = volts × amps for DC; watts = volts × amps × power factor for single-phase AC; watts = √3 × line-to-line volts × amps × power factor for three-phase.

How do I convert amps to watts on three-phase?

Multiply √3 × line-to-line volts × the current in one line × power factor. 10 A per line at 400 V and a power factor of 0.8 is 5,543 W.

How many watts is 20 amps at 12 V DC?

240 W. On DC the watts are simply volts × amps, with no power factor.

Sources

Last updated: