Electrical Unit Converters

These converters turn one electrical unit into another: watts to amps, amps to watts, kW and kVA, VA to watts and amp hours to watt hours. Pick the supply first, a DC battery, single-phase or three-phase mains, because the same watts draw very different amps on each. Every result shows the formula with your numbers.

Watts to amps: the current an appliance or circuit draws

To find the current an appliance draws, use the watts to amps calculator for any supply. For a battery or solar circuit, the twelve-volt watts to amps calculator; for mains in Pakistan, the watts to amps calculator for a home supply; for a three-phase connection, the three-phase amps calculator, which also takes kW or kVA.

Amps or volts to power: from a meter or clamp reading to watts

To go the other way, from the amps on a meter or clamp to power, use amps to watts or amps to kW; with the voltage and current you measured, the volts to watts calculator multiplies them for you.

Generator, UPS and battery ratings: kVA, VA and amp hours

Generators and UPS units are rated in kVA or VA, not watts: the kVA to kW calculator and the VA to watts calculator give the real power they can carry. Batteries are rated in amp hours; the Ah to Wh calculator turns that into the energy they store.

  • kVA to kW Calculator

    Convert kVA to kW using power factor. See why a 5 kVA generator or UPS gives about 4 kW at PF 0.8, with a table for common sizes.

  • VA to Watts Calculator

    Convert a UPS or inverter VA rating to real watts using power factor. Find how many watts a 1000VA or 1500VA UPS can actually run.

  • Amp Hours to Watt Hours (Ah to Wh) Calculator

    Convert battery amp-hours to watt-hours or kWh, and back. Pick 12V, 24V, 48V or 51.2V lithium; the page shows how depth of discharge cuts usable energy.

Key facts

  • Amps = watts ÷ (volts × power factor). On a 230 V single-phase supply, 1,500 W at a power factor of 0.8 draws 8.15 A.
  • kW = kVA × power factor, so at the usual generator power factor of 0.8 every kVA gives 0.8 kW of real power.
  • Watt hours = amp hours × volts, so a 200 Ah 12 V battery stores 2,400 Wh (2.4 kWh) and a 100 Ah 12 V battery stores 1,200 Wh (1.2 kWh).

Why the power factor matters

On AC mains, watts = volts × amps × power factor. A heater or kettle has a power factor of one, but motors, compressors and electronics draw some current that does no work, so a mixed home load is planned at 0.8 and a generator at 0.8. On a DC battery there is no power factor: the amps are simply the watts divided by the volts.

Frequently asked questions

How do I convert watts to amps?

Divide the watts by the volts; on AC mains also divide by the power factor, and on three-phase by √3 × the line voltage instead. The watts to amps calculator does it for DC, single-phase and three-phase supplies and shows each step.

Is kVA the same as kW?

No. kVA is apparent power and kW is real power: kW = kVA × power factor. At the usual generator power factor a set delivers about 80% of its kVA rating as kW, which is why a generator or UPS label overstates the load it can carry.

Which voltage should I use for Pakistan?

230 V for a single-phase home and 400 V between lines for a three-phase connection, at fifty hertz. Older labels may give a slightly lower nominal voltage; the difference in amps is small.

How do I find the watt hours of a battery?

Multiply its amp hours by its voltage. Only part of that energy is usable: about 50% for a tubular battery and 90% for lithium, which the battery and UPS calculators apply for you.

Sources

Last updated: